Modbus Client/Poll Server/Simulator, TCP/IP, Bluetooth/BLE, RS232 Serial Port
This Modbus App has three Apps in one. Android Modbus Master/Client/Poll, Slave/Server/Simulator, and Sensors Server. This simple to use utility is simple has many advanced features unmatched even by PC-based standards. > Choose 4 Interfaces: (1) Bluetooth SPP & BLE, (2) Ethernet, (3) Wi-Fi, (4) RS232/485 USB Serial ports (USB OTG capable devices)> Choose from 8 Modbus Protocols: Modbus TCP, Enron/Daniels TCP, Modbus RTU over TCP, Modbus UDP, Modbus RTU over UDP, Modbus TCP Slave/Server, Modbus RTU, Modbus Serial ASCII > Explore Sensor Server: Remotely monitor mobile devices sensors using Modbus Protocol (sensors such as Gyro, GPS, *Cell Phone Tower, etc.) remotely with built-in Modbus Sensor Server> Log data to ThinkSpeak platform: Graphically log and view data on ThinkSpeak cloud.> Log data Google Sheets: Use phone sensor (or any polled data) and log values straight into your private Google Spreadsheet in the cloud!!! The same Google Sheet can be used to centrally log values from different mobile devices into one Google Sheet (one file per device or all devices). > Easy to use Import/Export: Import in CSV format. Export data to CSV format every second, minute, or hour. Export configuration data via email or log to ThinkSpeak or Google Sheets Cloud platforms > Modbus Functions: FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, Write Auto Pick> Simple 6 digit Input Modbus Address input> Push to write pre-set value > Convert Modbus Integer Values to Text (Coded Message or Status Converter)> Data Conversion: Unsigned, Signed, Hex, Binary, Long, Double, Float, String, BCD formats, Unix Epoch Time, PLC Scaling (Bipolar/Unipolar Analog ADC value conversion)> Pro Tuning Options: Interval, Inter-Packet Delay, Link-Timeout, Actual RX/TX Counts> Bluetooth Requirement1. Your device must have Bluetooth Radio that supports SPP profile (RFCOMM Secure or Insecure)2. See "ModbusMonitor.com" or email
[email protected] for help3. See below for hardware requirements> USB-to-Serial Port Requirement, USB OTG Serial Ports>> RS232/422/RS485Your device must meet all of the THREE requirements.1. Your device must be Android version 3.2 or newer2. Your device must support USB Host or OTG interface3. Your USB-to-Serial Port dongle must contain one of following chipsets: >FTDI [FT230X, FT231X, FT234XD, FT232R, or FT232H], Prolific [PL2303HXD, PL2303EA, or PL2303RA], SiLab [CP210x], QinHeng CH34x 4. RS485: Tested with "no echo" setting turned ON. More: www.modbusmonitor/guide/serialport> Feedbackwww.ModbusMonitor.com contains an online form in the "Feeback" section for those interested in providing constructive feedback or feature requests.> Help- www.modbusmonitor.com/help- email:
[email protected] Google Sheets Login ErrorAdd-On added - ThingSpeak IoT Cloud Logging (MathWorks)Transforms Address when updating from old versionsAdded Transform Button when a manual update is needed anytime